Converts a positive signal to a negative signal.
- Ideal for operating the KO Gas Sensor with positive alarm output to the Snapper Can Bus alarm system with negative alarm input.
- Replaces costly relay circuitry.
- Converts positive door contact signals (e.g. truck range +24 volts) to negative signals (-24 volts) for connection to Snapper 24 volt alarm.
Technical data:
Output voltage: 12 - 30 VDC
Output current: max. 1A
Cable length: 9 cm
Assignment:
Cable: BLACK = Ground
Cable: GREEN = (-) signal output negative
Cable: RED = continuous positive +12 to 30 volts
Cable: YELLOW = (+) input signal positive